Release date

 

TypeQuality Update
Version7.2.1.1670
Security advice

-

You do not have the latest version of ECSTA yet?

Download →

Please make a backup of your environment before every update.

Bug fixes/Improvements

General

  • ECSTA no longer reports the controller call for LINECALLSTATE_CONFERENCED. 


    Background

    Since the Microsoft update in August 2026, there have been increasing instances of the problem where when exiting a conference call, calls in TSP "get stuck".

    Cause

    The entire TAPI subsystem is up and running and is no longer reporting any events. Hanging up/ending a telephone call still works. However, as no events are being processed, this is no longer visible.

    This means that control requests to the TAPI application also go unanswered. 
  • ECSTA 7 no longer supports 32-bit operating systems. It can now only be installed on 64-bit operating systems.

  • It is not possible to downgrade from ECSTA 7 to ECSTA 6.

Language variants

  • Deutsch/German (Standard) - de-DE
  • English (United States) - en-US

estos Product combination

The following combinations with estos products have been approved for use with ECSTA 7. 

  • ProCall 8 
  • ProCall 7 Enterprise (End of Life)

Upgrade

When upgrading an existing ECSTA installation, please ensure you follow the Notes on the upgrade process .

Be sure to back up your system before making any changes to an existing installation.

Known issues and limitations

ECSTA 7 known problems and limitations →

Further information

Overview →

Supported PBX →

System requirements →

ECSTA product page →