Generating a debug log for ECSTA for SIP phones
April 2021
This article supports you in activating the so-called debug logging in the ECSTA middleware and providing the corresponding log files for analysis.
Log files can only be examined if meaningful anchor points are available. Therefore always provide the following additional information
- When did the error occur (timestamp with date and time, at least to the minute)?
- Which internal extensions were involved?
- Which external participants were involved?
- Process of the workflow that led to an error
For meaningful processing, all available log files (preferably the complete packed c:\ecsta...\ directory) should always be provided.
Procedure
Microsoft Windows Control Panel
- Open the menu item Advanced Telephone Driver option (also accessible via the Start menu).
- In the following view, select the respective driver and open its configuration by clicking the button Configure...
- Switch to the Info tab in the ECSTA configuration and set the following settings.
Example screenshot
Note on data volume
Since the amount of data can grow rapidly, it is also recommended to check the box Delete log files daily, unless it is mandatory to log over several days.
If the driver log is already activated and has been running for some time, please first delete the old logs in the specified log files path.
Providing the log files
Click on the button "Provide logfiles" and all necessary log files are provided on the desktop as ZIP files.
Special features of ECSTA for SIP phones
Define the number of SIP files
In ECSTA for SIP phones, you can define how many SIP files should be created during logging operations. If the maximum amount (default 5) is reached, the oldest file is overwritten after reaching the maximum size.
Define the size of SIP files
In the same way, you can set the maximum size of these files.
Adjusting the log file quantity or size makes sense when analyzing larger environments, as this allows you to cover a longer period of time.
Registry settings
Please make the following setting for an adjustment in the registry:
ECSTA for SIP phones
"HKEY_LOCAL_MACHINE\SOFTWARE\ESTOS\ecstaSIPPhones"
MaxLogFileCount: Sets the number of SIP files to be written (default 5)
MaxLogFileSize: Defines the size of the files to be written (default 10)
uaCTSA server