ProCall DataCenter known problems and limitations
August 2024
General
Reference | Description | Affected versions | Status |
---|---|---|---|
PROCALL-1237 | ProCall DataCenter is not suitable for use with Active Directory AD SnapIns (schema extension). | >=2206.0 | UNRESOLVED |
EG-118 | Existing ProCall Enterprise configuration prevents correct ProCall DataCenter installation If a user is moved from one UCServer to another (change of home server), then the line becomes active on one UCServer immediately, but remains active on the other UCServer for about 15-30 seconds. I.e. for a short time the line is active on both UCServers. | >=2206.0 | UNRESOLVEDWorkaround: start up the line manually. |
EG-712 | Existing ProCall Enterprise configuration prevents correct ProCall DataCenter installation Currently, existing configuration settings can only be applied via the path described in the installation instructions. For a correct installation, it must currently be ensured that no setting and configuration artifacts from ProCall Enterprise are on the system. | >=2206.0 | UNRESOLVED |
EG-58, EG-466 | Federation only via SIP proxy SIP federation can currently only be performed via a separate, upstream SIP proxy. | >=2206.0 | UNRESOLVED |
EG-465 | Different UCConnect IDs From the perspective of UCConnect, the UCServers of the multi-server environment act as independent servers and are not recognized as a multi-server environment. This means that each server receives its own UCConnect ID. If a user changes a server and uses Mobility Services or ProCall Meetings, the server ID must be updated in their user login. | >=2206.0 | UNRESOLVED |
EG-1032 | Blacklist for callers (forwardings.xml) in DataCenter The blacklist is currently not synchronized across servers. This must be distributed to all servers administratively manually . | >=2206.0 | UNRESOLVED |
EG-588 | Monitor and favorite contacts Contacts in the monitor or favorites are not moved when the server is changed and are therefore not available on the other server. | <2210.0 | RESOLVED (2210.0) |
EG-164, EG-508 | Computer profiles cannot be assigned across servers Computer profiles can be used to assign a phone number to a computer, which is bound to the user as soon as he logs on to this PC. Since the user and the line must currently be on the same server, it cannot be guaranteed that this will work for all users, since they may be registered on a different home server than the corresponding line. | >=2206.0 | UNRESOLVED |
EG-890 | UCConnect services are not available The use of UCConnect services in conjunction with ProCall DataCenter is currently not possible. | >=2306.0 | UNRESOLVED |
EG-954 | When saving in UCServer administration, the connection to the configuration database is incorrectly displayed as connected. If the configuration database is not connected, a warning message is correctly displayed. If a change is nevertheless made to the configuration and the configuration is accepted, the warning message is incorrectly removed and the configuration database is displayed as connected, although it is still not connected. | >=2306.0 | UNRESOLVED |
ProCall Enterprise
Please also refer to the ProCall Enterprise known problems and limitations for changes that do not explicitly affect ProCall DataCenter, but also affect ProCall Enterprise.